Reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690VAC, 48 to 72VAC/DC coil, without control terminals
Low-voltage industrial components, TeSys U
Reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690VAC, 48 to 72VAC/DC coil, without control terminals
Availability:
Out of stock
Reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690VAC, 48 to 72VAC/DC coil, without control terminals
1,304.00 ر.س
Out of stock
| Type of electrical connection of main circuit | Screw connection |
| Number of indicator lights | 0 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V | 10000 Ampere |
| Supporting protocol for SERCOS | No |
| Rated operation power at AC-3, 400 V | 5.5 Kilowatt |
| Rated conditional short-circuit current, type 2, 230 V | 50000 Ampere |
| Rated operation current Ie | 12 Ampere |
| Rated conditional short-circuit current, type 1, 600 Y/347 V | 4000 Ampere |
| Ambient temperature, upper operating limit | 70 Degrees celsius |
| External reset possible | No |
| With transformer | No |
| Type of electrical connection for auxiliary- and control current circuit | Screw connection |
| Rated operation current at AC-3, 400 V | 12 Ampere |
| Rated conditional short-circuit current, type 2, 400 V | 50000 Ampere |
| Voltage type for actuating | AC/DC |
| Height | 224 Millimetre |
| Supporting protocol for INTERBUS-Safety | No |
| Number of command positions | 3 |
| Width | 45 Millimetre |
| Number of auxiliary contacts as normally closed contact | 1 |
| Supporting protocol for AS-Interface Safety at Work | No |
| Number of auxiliary contacts as normally open contact | 1 |
| Coordination class according to IEC 60947-4-3 | Class 2 |
| Depth | 126 Millimetre |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Rated operation power at AC-3, 230 V, 3-phase | 3 Kilowatt |
| Supporting protocol for ASI | No |
| Type of motor starter | Reversing starter |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for TCP/IP | No |
| Degree of protection (IP) | IP20 |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Rated control supply voltage AC 50 Hz | 48 Volt Volt |
| Rated control supply voltage AC 60 Hz | 48 Volt Volt |
| Rail mounting possible | Yes |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Suitable for emergency stop | No |
| Supporting protocol for LON | No |
| With fuse | No |
| Supporting protocol for other bus systems | No |
| With short-circuit release | Yes |
| Supporting protocol for SUCONET | No |
| Rated power, 575 V, 60 Hz, 3-phase | 5.5 Kilowatt |
| Rated power, 460 V, 60 Hz, 3-phase | 5.5 Kilowatt |
| Rated control supply voltage DC | 48…72 Volt Volt |
- 📄 PP_EUdec__EU1007946-1-TeSysU-LUB
- 📄 TeSys Ultra - LU2B./LU2M./LU6M. Reversing Power Bases - Instruction Sheet