Type of electrical connection of main circuitScrew connection
Number of indicator lights0
Rated conditional short-circuit current, type 1, 480 Y/277 V10000 Ampere
Supporting protocol for SERCOSNo
Rated operation power at AC-3, 400 V5.5 Kilowatt
Rated conditional short-circuit current, type 2, 230 V50000 Ampere
Rated operation current Ie12 Ampere
Rated conditional short-circuit current, type 1, 600 Y/347 V4000 Ampere
Ambient temperature, upper operating limit70 Degrees celsius
External reset possibleNo
With transformerNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated operation current at AC-3, 400 V12 Ampere
Rated conditional short-circuit current, type 2, 400 V50000 Ampere
Voltage type for actuatingAC/DC
Height224 Millimetre
Supporting protocol for INTERBUS-SafetyNo
Number of command positions3
Width45 Millimetre
Number of auxiliary contacts as normally closed contact1
Supporting protocol for AS-Interface Safety at WorkNo
Number of auxiliary contacts as normally open contact1
Coordination class according to IEC 60947-4-3Class 2
Depth126 Millimetre
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 230 V, 3-phase3 Kilowatt
Supporting protocol for ASINo
Type of motor starterReversing starter
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP20
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Rated control supply voltage AC 50 Hz48 Volt Volt
Rated control supply voltage AC 60 Hz48 Volt Volt
Rail mounting possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Suitable for emergency stopNo
Supporting protocol for LONNo
With fuseNo
Supporting protocol for other bus systemsNo
With short-circuit releaseYes
Supporting protocol for SUCONETNo
Rated power, 575 V, 60 Hz, 3-phase5.5 Kilowatt
Rated power, 460 V, 60 Hz, 3-phase5.5 Kilowatt
Rated control supply voltage DC48…72 Volt Volt