variable speed drive, Altivar Process ATV600, ATV630, 7.5kW, 10hp, 200 to 240V, IP21, UL type 1
Altivar Process ATV600, Low-voltage industrial components
variable speed drive, Altivar Process ATV600, ATV630, 7.5kW, 10hp, 200 to 240V, IP21, UL type 1
Availability:
Out of stock
variable speed drive, Altivar Process ATV600, ATV630, 7.5kW, 10hp, 200 to 240V, IP21, UL type 1
13,231.00 ر.س
Out of stock
| Number of HW-interfaces parallel | 0 |
| Number of interfaces PROFINET | 0 |
| Supporting protocol for SERCOS | No |
| Number of HW-interfaces other | 0 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 0 |
| Type of converter | U converter |
| With optical interface | No |
| Mains voltage | 200…240 Volt Volt |
| Max. output frequency | 500 Hertz |
| Height | 405 Millimetre |
| Supporting protocol for INTERBUS-Safety | No |
| Mains frequency | 50/60 Hz |
| Width | 173 Millimetre |
| With control element | Yes |
| With PC connection | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Number of phases input | 3 |
| Depth | 231 Millimetre |
| Max. output at quadratic load at rated output voltage | 7.5 Kilowatt |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Max. output at linear load at rated output voltage | 7.5 Kilowatt |
| Number of phases output | 3 |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | Yes |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for ASI | No |
| Relative symmetric net voltage tolerance | 10 Percentage |
| Supporting protocol for PROFIBUS | Yes |
| Relative symmetric net frequency tolerance | 5 Percentage |
| Supporting protocol for TCP/IP | Yes |
| Application in domestic- and commercial area permitted | Yes |
| Supporting protocol for KNX | No |
| Degree of protection (IP) | IP21 |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Integrated breaking resistance | No |
| Application in industrial area permitted | Yes |
| Supporting protocol for BACnet | No |
| Supporting protocol for DeviceNet | Yes |
| Number of digital outputs | 0 |
| Supporting protocol for Modbus | Yes |
| Number of digital inputs | 6 |
| Supporting protocol for Data-Highway | No |
| Number of analogue outputs | 2 |
| Number of analogue inputs | 3 |
| 4-quadrant operation possible | Yes |
| Supporting protocol for LON | No |
| Supporting protocol for other bus systems | No |
| Supporting protocol for SUCONET | No |
| Number of HW-interfaces RS-422 | 0 |
| Nominal output current I2N | 32.7 Ampere |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces RS-232 | 0 |
| Max. output voltage | 240 Volt |
- 📄 ATV630 & ATV650 UK DECLARATION
- 📄 Altivar Process ATV630, Variable speed drive, 22kW, 380 to 480V, 3 phases, IP21 - Product End-of-Life Instructions - EN - V4
- 📄 Altivar Process ATV630, Variable speed drive, 22kW, 380 to 480V, 3 phases, IP21 - Product Environmental Profile - EN - V4
- 📄 1) Getting Started with ATV630/ATV650
- 📄 ATV630-650 Installation manual
- 📄 video: How to setup S2 Redundancy communication between Altivar and Siemens PLCs ? (using PROFINET module VW3A3647 in TIA Portal)
- 📄 Discover catalog for Altivar Process ATV600 variable speed drives
- 📄 Variable speed drive ATV630 - 380...440 V - floor standing - 3D CAD
- 📄 360 set of image
Based on 0 reviews
Only logged in customers who have purchased this product may leave a review.








There are no reviews yet.